Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(22): 222501, 2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37327448

RESUMO

The ß-delayed proton decay of ^{13}O has previously been studied, but the direct observation of ß-delayed 3αp decay has not been reported. Rare 3αp events from the decay of excited states in ^{13}N^{⋆} provide a sensitive probe of cluster configurations in ^{13}N. To measure the low-energy products following ß-delayed 3αp decay, the Texas Active Target (TexAT) time projection chamber was employed using the one-at-a-time ß-delayed charged-particle spectroscopy technique at the Cyclotron Institute, Texas A&M University. A total of 1.9×10^{5} ^{13}O implantations were made inside the TexAT time projection chamber. A total of 149 3αp events were observed, yielding a ß-delayed 3αp branching ratio of 0.078(6)%. Four previously unknown α-decaying excited states were observed in ^{13}N at 11.3, 12.4, 13.1, and 13.7 MeV decaying via the 3α+p channel.


Assuntos
Prótons , Humanos , Análise Espectral
2.
Phys Rev Lett ; 121(5): 052501, 2018 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-30118303

RESUMO

Obtaining reliable data for nuclear reactions on unstable isotopes remains an extremely important task and a formidable challenge. Neutron capture cross sections-crucial ingredients for models of astrophysical processes, national security applications, and simulations of nuclear energy generation-are particularly elusive, as both projectile and target in the reaction are unstable. We demonstrate a new method for determining cross sections for neutron capture on unstable isotopes, using ^{87}Y(n,γ) as a prototype. To validate the method, a benchmark experiment is carried out to obtain the known ^{90}Zr(n,γ) cross section analogously. Our approach, which employs an indirect ("surrogate") measurement combined with theory, can be generalized to a larger class of nuclear reactions. It can be used both with traditional stable-beam experiments and in inverse kinematics at rare-isotope facilities.

3.
Phys Rev Lett ; 119(23): 232501, 2017 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-29286688

RESUMO

We study the sequential breakup of E/A=24.0 MeV ^{7}Li projectiles excited through inelastic interactions with C, Be, and Al target nuclei. For peripheral events that do not excite the target, we find very large spin alignment of the excited ^{7}Li projectiles longitudinal to the beam axis. This spin alignment is independent of the target used, and we propose a simple alignment mechanism that arises from an angular-momentum-excitation-energy mismatch. This mechanism is independent of the potential used for scattering and should be present in many scattering experiments.

4.
Appl Radiat Isot ; 71(1): 34-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23085548

RESUMO

Pure samples of (131m)Xe, (133m)Xe, (133)Xe and (135)Xe facilitate the calibration and testing of noble gas sampler stations and related laboratory instrumentation. We have earlier reported a Penning trap-based production method for pure (133m)Xe and (133)Xe samples. Here we complete the work by reporting the successful production of pure (131m)Xe and (135)Xe samples using the same technique. In addition, we present data on xenon release from graphite.

5.
Phys Rev Lett ; 109(3): 032501, 2012 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-22861839

RESUMO

Atomic masses of the neutron-rich isotopes (121-128)Cd, (129,131)In, (130-135)Sn, (131-136)Sb, and (132-140)Te have been measured with high precision (10 ppb) using the Penning-trap mass spectrometer JYFLTRAP. Among these, the masses of four r-process nuclei (135)Sn, (136)Sb, and (139,140)Te were measured for the first time. An empirical neutron pairing gap expressed as the odd-even staggering of isotopic masses shows a strong quenching across N = 82 for Sn, with a Z dependence that is unexplainable by the current theoretical models.

6.
Phys Rev Lett ; 108(16): 162502, 2012 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-22680713

RESUMO

A measurement of the final state distribution of the (8)B ß decay, obtained by implanting a (8)B beam in a double-sided silicon strip detector, is reported here. The present spectrum is consistent with a recent independent precise measurement performed by our collaboration at the IGISOL facility, Jyväskylä [O. S. Kirsebom et al., Phys. Rev. C 83, 065802 (2011)]. It shows discrepancies with previously measured spectra, leading to differences in the derived neutrino spectrum. Thanks to a low detection threshold, the neutrino spectrum is for the first time directly extracted from the measured final state distribution, thus avoiding the uncertainties related to the extrapolation of R-matrix fits. Combined with the IGISOL data, this leads to an improvement of the overall errors and the extension of the neutrino spectrum at high energy. The new unperturbed neutrino spectrum represents a benchmark for future measurements of the solar neutrino flux as a function of energy.

7.
Physiol Meas ; 31(3): 427-38, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20150689

RESUMO

The objective of the present work was to develop new computational parameters to examine the characteristics of respiratory cycle phases from the tracheal breathing sound signal during sleep. Tracheal sound data from 14 patients (10 males and 4 females) were examined. From each patient, a 10 min long section of normal and a 10 min section of flow-limited breathing during sleep were analysed. The computationally determined proportional durations of the respiratory phases were first investigated. Moreover, the phase durations and breathing sound amplitude levels were used to calculate the area under the breathing sound envelope signal during inspiration and expiration phases. An inspiratory sound index was then developed to provide the percentage of this type of area during the inspiratory phase with respect to the combined area of inspiratory and expiratory phases. The proportional duration of the inspiratory phase showed statistically significantly higher values during flow-limited breathing than during normal breathing and inspiratory pause displayed an opposite difference. The inspiratory sound index showed statistically significantly higher values during flow-limited breathing than during normal breathing. The presented novel computational parameters could contribute to the examination of sleep-disordered breathing or as a screening tool.


Assuntos
Transtornos Respiratórios/fisiopatologia , Respiração , Sons Respiratórios , Sono/fisiologia , Traqueia/fisiologia , Adolescente , Adulto , Algoritmos , Área Sob a Curva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Processamento de Sinais Assistido por Computador , Espectrografia do Som , Fatores de Tempo , Adulto Jovem
8.
Appl Radiat Isot ; 68(3): 450-3, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20044263

RESUMO

A Penning trap-based purification process having a resolution of about 1 ppm is reported. In this context, we present for the first time a production method for the most complicated and crucially important nuclear weapons test signature, (133m)Xe. These pure xenon samples are required by the Comprehensive Nuclear-Test-Ban Treaty Organization to standardize and calibrate the worldwide network of xenon detectors.

9.
Phys Rev Lett ; 105(20): 202501, 2010 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-21231223

RESUMO

The ß feeding probability of (102,104,105,106,107)Tc, 105Mo, and 101Nb nuclei, which are important contributors to the decay heat in nuclear reactors, has been measured using the total absorption technique. We have coupled for the first time a total absorption spectrometer to a Penning trap in order to obtain sources of very high isobaric purity. Our results solve a significant part of a long-standing discrepancy in the γ component of the decay heat for 239Pu in the 4-3000 s range.

10.
Phys Rev Lett ; 102(22): 222501, 2009 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-19658859

RESUMO

A new method of optical pumping in an ion beam cooler buncher has been developed to selectively enhance ionic metastable state populations. The technique permits the study of elements previously inaccessible to laser spectroscopy and has been applied here to the study of Nb. Model independent mean-square charge radii and nuclear moments have been studied for ;{90,90 m,91,91 m,92,93,99,101,103}Nb to cover the region of the N=50 shell closure and N approximately 60 sudden onset of deformation. The increase in mean-square charge radius is observed to be less than that for Y, with a substantial degree of beta softness observed before and after N=60.

11.
Phys Rev Lett ; 102(25): 252501, 2009 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-19659070

RESUMO

The nuclides 104-108Sn, 106-110Sb, 108,109Te, and 111I at the expected endpoint of the astrophysical rp process have been produced in 58Ni+natNi fusion-evaporation reactions at IGISOL and their mass values were precisely measured with the JYFLTRAP Penning trap mass spectrometer. For 106Sb, 108Sb, and 110Sb these are the first direct experimental mass results obtained. The related one-proton separation energies have been derived and the value for 106Sb, Sp=424(8) keV, shows that the branching into the closed SnSbTe cycle in the astrophysical rp process is weaker than expected.

12.
Comput Biol Med ; 39(11): 1000-5, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19712930

RESUMO

We present two methods for identifying respiratory cycle phases from tracheal sound signal during sleep. The methods utilize the Hilbert transform in envelope extraction. They determine automatically a patient-specific amplitude threshold to be used in the detection. The core of one method is designed to be amplitude-independent whereas the other method uses solely the amplitude information. The methods provided average sensitivities of 98% and 99%, respectively, and positive prediction values of 100% on the total of 1434 respiratory cycles analysed from six different patients. The developed methods seem promising as such or as tools for analysing sleep disordered breathing.


Assuntos
Fenômenos Fisiológicos Respiratórios , Sono/fisiologia , Traqueia/fisiologia , Humanos
13.
Physiol Meas ; 30(5): 467-78, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19349649

RESUMO

A nasal pressure transducer, which is used to study nocturnal airflow, also provides information about the inspiratory flow waveform. A round flow shape is presented during normal breathing. A flattened, non-round shape is found during hypopneas and it can also appear in prolonged episodes. The significance of this prolonged flow limitation is still not established. A tracheal sound spectrum has been analyzed further in order to achieve additional information about breathing during sleep. Increased sound frequencies over 500 Hz have been connected to obstruction of the upper airway. The aim of the present study was to examine the tracheal sound signal content of prolonged flow limitation and to find out whether prolonged flow limitation would consist of abundant high frequency activity. Sleep recordings of 36 consecutive patients were examined. The tracheal sound spectral analysis was performed on 10 min episodes of prolonged flow limitation, normal breathing and periodic apnea-hypopnea breathing. The highest total spectral amplitude, implicating loudest sounds, occurred during flow-limited breathing which also presented loudest sounds in all frequency bands above 100 Hz. In addition, the tracheal sound signal during flow-limited breathing constituted proportionally more high frequency activities compared to normal breathing and even periodic apnea-hypopnea breathing.


Assuntos
Ventilação Pulmonar , Mecânica Respiratória , Síndromes da Apneia do Sono/fisiopatologia , Traqueia/fisiologia , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Espectrografia do Som , Adulto Jovem
14.
Med Biol Eng Comput ; 47(4): 405-12, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19205772

RESUMO

Sleep apnoea syndrome is common in the general population and is currently underdiagnosed. The aim of the present work was to develop a new tracheal sound feature for separation of apnoea events from non-apnoea time. Ten overnight recordings from apnoea patients containing 1,107 visually scored apnoea events totalling 7 h in duration and 72 h of non-apnoea time were included in the study. The feature was designed to describe the local spectral content of the sound signal. The median, maximum and mean smoothing of different time scales were compared in the feature extraction. The feature was designed to range from 0 to 1 irrespective of tracheal sound amplitudes. This constant range could offer application of the feature without patient-specific adjustments. The overall separation of feature values during apnoea events from non-apnoea time across all patients was good, reaching 80.8%. Due to the individual differences in tracheal sound signal amplitudes, developing amplitude-independent means for screening apnoea events is beneficial.


Assuntos
Auscultação/métodos , Síndromes da Apneia do Sono/diagnóstico , Traqueia/fisiopatologia , Adulto , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Espectrografia do Som/métodos , Vibração
15.
Med Biol Eng Comput ; 47(1): 3-10, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18679736

RESUMO

All-night EEG recordings from 12 male apnea patients and 12 age-matched healthy control subjects were studied in the present work. The spectral mean frequency was used to provide computational sleep depth curves from two frontopolar and two central EEG channels. Our previously presented computational parameters quantifying the properties of the sleep depth curves were improved. The resulting light sleep percentage (LS%) values were higher in apnea patients than in control subjects in the right central brain position (P = 0.028), in concordance to our previous work. Moreover, apnea patients showed higher LS% values in the right frontopolar position (P = 0.008). Also, apnea patients showed a smaller anteroposterior sleep depth difference than control subjects on the right hemisphere (P = 0.002). These are interesting new findings, achieved by the present methodology. Thus, the developed computational parameters were able to quantify, at least to some degree, the disruption of sleep process caused by the recurrent apneic events.


Assuntos
Síndromes da Apneia do Sono/fisiopatologia , Adulto , Idoso , Estudos de Casos e Controles , Eletroencefalografia/métodos , Lobo Frontal/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Processamento de Sinais Assistido por Computador , Fases do Sono
16.
Phys Rev Lett ; 103(25): 252501, 2009 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-20366251

RESUMO

The superallowed beta-decay Q(EC) values of (34)Cl and (38)K(m) have been measured with an online Penning trap to be 5491.662(47) keV and 6044.223(41) keV, respectively. The new values are more precise than the previous high-precision reaction-based values but are consistent with them and establish that there are no significant systematic differences between the two types of measurements.

17.
Phys Rev Lett ; 101(14): 142503, 2008 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-18851523

RESUMO

Nuclides in the vicinity of 94Ag have been studied with the Penning trap mass spectrometer JYFLTRAP at the Ion-Guide Isotope Separator On-Line. The masses of the two-proton-decay daughter 92Rh and the beta-decay daughter 94Pd of the high-spin isomer in 94Ag have been measured, and the masses of 93Pd and 94Ag have been deduced. When combined with the data from the one-proton- or two-proton-decay experiments, the results lead to contradictory mass excess values for the high-spin isomer in 94Ag, -46 370(170) or -44 970(100) keV, corresponding to excitation energies of 6960(400) or 8360(370) keV, respectively.

18.
Phys Rev Lett ; 101(5): 052502, 2008 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-18764386

RESUMO

Atomic masses of the neutron-rich isotopes (76-80)Zn, (78-83)Ga, (80-85)Ge, (81-87)As, and (84-89)Se have been measured with high precision using the Penning trap mass spectrometer JYFLTRAP at the IGISOL facility. The masses of (82,83)Ga, (83-85)Ge, (84-87)As, and 89Se were measured for the first time. These new data represent a major improvement in the knowledge of the masses in this neutron-rich region. Two-neutron separation energies provide evidence for the reduction of the N=50 shell gap energy towards germanium (Z=32) and a subsequent increase at gallium (Z=31). The data are compared with a number of theoretical models. An indication of the persistent rigidity of the shell gap towards nickel (Z=28) is obtained.

19.
Phys Rev Lett ; 100(13): 132502, 2008 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-18517940

RESUMO

Using a new fast cleaning procedure to prepare isomerically pure ion samples, we have measured the beta-decay Q(EC) values of the superallowed beta emitters 5(0)Mn and (54)Co to be 7634.48(7) and 8244.54(10) keV, respectively, results which differ significantly from the previously accepted values. The corrected Ft values derived from our results strongly support new isospin-symmetry-breaking corrections that lead to a higher value of the up-down quark mixing element V(ud) and improved confirmation of the unitarity of the Cabibbo-Kobayashi-Maskawa matrix.

20.
J Neurosci Methods ; 172(1): 54-9, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-18482770

RESUMO

The objective of the present work was to examine fronto-central spindle frequency. A previously validated spindle detector, providing an electroencephalographic (EEG) amplitude independent spindle detection, was used to detect bilateral sleep spindles from sleep EEG recordings of ten healthy subjects with a time resolution of 0.33-s. A bilateral spindle detected centrally and frontopolarly simultaneously is called here a diffuse spindle. A bilateral spindle detected only frontopolarly or centrally at a given time is called a pure frontopolar and a pure central spindle, respectively. Spindle frequency was obtained with zero-padded discrete Fourier transform (DFT). Waveform phase angle of diffuse spindles was also examined. A total of 1230 diffuse spindles and 5316 pure central and 2595 pure frontopolar spindles were detected. The difference of median spindle frequency between central and frontopolar brain positions was clearly smaller in diffuse spindles than in pure spindles. Moreover, 34% of the diffuse spindles showed a similar frequency in central and frontopolar locations. This figure was up to 50.9% when including the 700 diffuse spindles fulfilling a strict anteroposterior (AP) timing criteria. The timing criteria selection in diffuse spindle analysis is a new functionality, enabled by the present spindle analysis method. Diffuse spindles showed coherent spindle oscillation in a large fronto-central area. Pure frontopolar spindles might be special cases of diffuse spindles, both of them seem to be generated in the nucleus medialis dorsalis (NMD) of the thalamus.


Assuntos
Córtex Cerebral/fisiologia , Reconhecimento Automatizado de Padrão/métodos , Sono/fisiologia , Adulto , Córtex Cerebral/anatomia & histologia , Eletroencefalografia/métodos , Análise de Fourier , Lateralidade Funcional , Humanos , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...